← Regulatory Atlas

Cross-case comparison · Atlas v1.3

Regulatory Evidence Matrix

Compare pathway, disclosed AI function, validation design, change control, and postmarket boundaries across ten selected FDA case studies.

Public basis
10 selected cases
Jurisdiction
United States
Outcome benefit
0 established
Selection reviewed
Sep 9, 2026

What this comparison does

Places six regulatory dimensions beside one another so differences in pathway, disclosure, evidence, change control, and postmarket scope remain visible.

What it does not do

It is not a complete FDA market census, vendor ranking, purchasing guide, or proof that an authorized device improves patient outcomes.

Ten teaching cases

Compare the claim with its boundary.

Labels summarize the full case records. Follow a device name for the intended use, detailed validation, source links, and version-specific limits.

On narrow screens, scroll horizontally to compare all six columns.

Regulatory evidence comparison across ten selected FDA case studies
Device / functionFDA pathwayPublic AI disclosureStrongest validation designPCCP / change controlPostmarket boundary
SafeOp 3: Neural Informatix SystemK252842 · Monitoring 510(k)Substantial equivalence Algorithm / classifierControlled updates under a PCCP NonclinicalSoftware, electrical-safety, EMC, and nonclinical performance verification. PCCP authorizedIn K252842 Component / model recall matchScoped record; not a product-wide event rate
Brainomix 360 HyperdensityK260406 · Imaging 510(k)Substantial equivalence AI/ML explicitControlled updates under a PCCP Retrospective clinicalClinical image-set comparison against radiologist ground truth. PCCP authorizedIn K260406 No exact-name recall resultBounded search; not proof that no recall exists
Mazor X System / Mazor X Stealth EditionK251316 · Planning 510(k)Substantial equivalence AI/ML explicitLocked model or algorithm Retrospective clinicalRetrospective imaging evaluation plus expert assessment of suggested plans. No PCCP identifiedReviewed submission and FDA database record Product-family recall matchNot directly attributed to the indexed submission
SpineAR SNAP (SyncAR Spine)K252054 · Navigation 510(k)Substantial equivalence AI/ML explicitAdaptivity not established publicly Retrospective clinicalHeld-out CT and MR vertebral-segmentation evaluation. No PCCP identifiedReviewed submission and FDA database record Product-family recall matchNot directly attributed to the indexed submission
Acorn 3D Software (AC-SEG-4009); Acorn 3DP Model (AC-101-XX)K260322 · Planning 510(k)Substantial equivalence AI/ML explicitControlled updates under a PCCP NonclinicalSoftware, end-user, and bench testing of correction planning. Inherited PCCPAuthorized in K234009, not the indexed submission No exact-name recall resultBounded search; not proof that no recall exists
JLK-NCCTK252421 · Imaging 510(k)Substantial equivalence AI/ML explicitAdaptivity not established publicly Retrospective clinicalIndependent retrospective standalone and reader-performance evaluation for LVO. No PCCP identifiedReviewed submission and FDA database record No exact-name recall resultBounded search; not proof that no recall exists
BrainSeeDEN220066 · Prognosis De NovoNew device type Algorithm / classifierLocked model or algorithm Retrospective clinicalRetrospective pivotal validation using longitudinal clinical diagnoses. No PCCP identifiedReviewed submission and FDA database record Required performance studyNo exact-name recall result in the targeted search
BrainScope Ahead 100DEN140025 · Assessment De NovoNew device type Algorithm / classifierLocked model or algorithm Prospective clinicalProspective, blinded, 11-site US pivotal study. No PCCP identifiedReviewed submission and FDA database record No exact-name recall resultBounded search; not proof that no recall exists
EyeBOXDEN170091 · Assessment De NovoNew device type Algorithm / classifierLocked model or algorithm Prospective clinicalPivotal head-injury study; the clinical reference standard changed during the study. No PCCP identifiedReviewed submission and FDA database record Component / model recall matchScoped record; not a product-wide event rate
xvision Spine systemK251639 · Navigation 510(k)Substantial equivalence AI function not established publiclyAdaptivity not established publicly NonclinicalSoftware, accuracy, phantom, cadaver, and human-factors testing. No PCCP identifiedReviewed submission and FDA database record Component / model recall matchScoped record; not a product-wide event rate

Reading notes

The columns are related, but not interchangeable.

Pathway
510(k) and De Novo answer different regulatory questions; neither is an evidence grade.
Disclosure
FDA-list inclusion does not by itself identify a learning architecture, generative interface, or foundation model.
Validation
The matrix reports the strongest disclosed design, not a quality score. Nonclinical, retrospective, and prospective evidence support different claims.
Change control
An authorized PCCP permits bounded changes. It does not imply unrestricted or continuously self-learning operation.
Postmarket
Recall matches are version- and component-sensitive; a negative targeted search is not proof that no recall or event exists.